Page 58
P942E Zone tamper mapped to scenario 1-4
P943E “RF Interference” mapped to scenario 1-4
P944E Radio panic mapped to scenario 1-4
P945E Supervised radio timeout mapped to scenario 1-4
P946E Sensorwatch timeout mapped to scenario 1-4
P947E Test calls mapped to scenario 1-4
P948E Expander Fail mapped to scenario 1-4
P949E Expander Tamper mapped to scenario 1-4
P950E Callback mapped to scenario 1-4
PROGRAMMING TEST CALL OPTIONS - P816E - P817E
Because the panel has a real time clock, it is possible to assign test calls by day of the week and sync it to a
particular time of the day.
P816E 0-7 Test Call Days of the Week - Where 1 = Sunday and 7 = Saturday. 0 = No Test
P817E HHMM Test Call Time of Day - Where the time of the day you wish the panel to make its daily test
call is programmed in 24 hour format (HHMM).
CONTACT ID & SPEECH MESSAGE PROGRAMMING
CONTACT ID & SPEECH MESSAGE PROGRAMMINGCONTACT ID & SPEECH MESSAGE PROGRAMMING
CONTACT ID & SPEECH MESSAGE PROGRAMMING
CONTACT ID AREA ACCOUNT CODES - P676E, P776E, P876E & P976E
The special characters (B, C, D, E & F) can also be programmed at these locations (see chart on page 62 for details)
P676E XXXX Account Code for Area "A" - The Account code set at this address will be used to report all
system events Arms and Disarms, zone activations, restores and bypasses etc from Area "A"
P776E XXXX Account Code for Area "B" - The account code set at this address will be used to report Arms
and Disarms, zone activations, restores and bypasses etc from Area "B"
P876E XXXX Account Code for Area "C" - The account code set at this address will be used to report Arms
and Disarms, zone activations, restores and bypasses etc from Area "C"
P976E XXXX Account Code for Area "D" - The account code set at this address will be used to report Arms
and Disarms, zone activations, restores and bypasses etc from Area "D"
ZONE GROUP CONTACT ID ALARM REPORTING CODE - P551E-P570E
This is the Contact ID event code that the zone group will send when an alarm occurs on a zone assigned to that
group. The default setting is “130” which means a burglar alarm message will be sent. If you have panic alarms, fire
alarms or some other alarm type on specific groups you can re-program this code to identify the type of alarm
correctly.
P571E XXX Zone Group #1 Alarm reporting code Default = 130 0 = No Report
P572E XXX Zone Group #2 Alarm reporting code Default = 130
P573E XXX Zone Group #3 Alarm reporting code Default = 130
P574E XXX Zone Group #4 Alarm reporting code Default = 130
P575E XXX Zone Group #5 Alarm reporting code Default = 130
P576E XXX Zone Group #6 Alarm reporting code Default = 130
P577E XXX Zone Group #7 Alarm reporting code Default = 130
P578E XXX Zone Group #8 Alarm reporting code Default = 130
P579E XXX Zone Group #9 Alarm reporting code Default = 130
P580E XXX Zone Group #10 Alarm reporting code Default = 130
P581E XXX Zone Group #11 Alarm reporting code Default = 130
P582E XXX Zone Group #12 Alarm reporting code Default = 130
P583E XXX Zone Group #13 Alarm reporting code Default = 130
P584E XXX Zone Group #14 Alarm reporting code Default = 130
P585E XXX Zone Group #15 Alarm reporting code Default = 130
P586E XXX Zone Group #16 Alarm reporting code Default = 130
P587E XXX Zone Group #17 Alarm reporting code Default = 130
P588E XXX Zone Group #18 Alarm reporting code Default = 130
P589E XXX Zone Group #19 Alarm reporting code Default = 130
P590E XXX Zone Group #20 Alarm reporting code Default = 130
Kommentare zu diesen Handbüchern