DATA TRANSFER USING EE² BOARD (DTU)
P1098E Write to EE² Board - With the optional back-up EE² board plugged into the serial connector on the
panel and the write enable link fitted on the EE² board, entering P1098E will write a copy of the panel
program files to the EE² board.
P1099E Read from EE² Board - This address allows a copy of a panel program to be downloaded into the panel
(the program files must first have been copied to the EE² board - refer P1098E). Note: When transferring
data from this board to a panel, the software versions of the two panels (the panel where the data files
were created and the panel receiving the files) must be the same otherwise the panel may not work
correctly.
CLEAR OUTPUT DEFAULTS - P1106E
P1106E Clear Output Defaults - This option is used to remove ALL default options assigned to any output. This
is a particularly useful tool when reassigning outputs to special functions such as smoke detector reset,
garage door control, etc, where you need to remove the standard defaults from an output. In addition to
removing all default programming this option will also make the reset time for the selected output/s “0”.
RESET TO DEFAULTS
RESET TO DEFAULTSRESET TO DEFAULTS
RESET TO DEFAULTS
RESET TO DEFAULTS - P1100E - P1105E
These addresses are used to reset sections of the programming back to defaults. Defaults are the factory settings.
To reset the entire configuration, including the event memory buffer you can use P1105E, otherwise you can default
selected sections of memory as described below. To perform the default functions you must enter in the address as
below then repeat the address number eg P1105E 1105E. The second entry is designed to prevent accidental
defaulting of the panel.
P1100E Reset User codes
P1101E Reset Dialler parameters
P1102E Reset Radio parameters
P1103E Reset Voice settings
P1104E Reset the balance of the panel settings not included above
P1105E Reset all panel parameters to default and clear the event memory buffer
CLEAR EVENT MEMORY - P1107E
The panel stores up to 255 events in its non-volatile memory. When the memory reaches the limit, the newest event
will replace the oldest event. This address allows you to clear all currently stored events. To perform the memory
reset function you must enter in the address as below then repeat the address number eg P1107E 1107E. The
second entry is designed to prevent accidental deletion of the memory events.
START CALLBACK - P1108E
For Security reasons it is possible to restrict access to the control panel for re-programming via a PC by only allowing
callback. For the callback option to work there must be a telephone number programmed with the callback format
(P837E-P842E option 14) and callback must be enabled (P743E option 1 On). For a User to initiate a callback the
user must have a user group assigned to it that has option 4 turned on at addresses P221E-P240E. If all of the above
is set-up properly, the user can access Client program mode then enter P1108E at the keypad and the panel will then
dial the pre-programmed Callback number.
P1108E Start Callback
RESET PANEL - P1109E
If one of the expanders is not intended to be connected to the control panel but a hardwired zone group is
accidentally assigned to a zone on the non-connected expander, the panel will try to update the expander and an
expander fail will occur. Once the incorrect programming has been corrected the panel either has to be powered
down to reset the expander fail alarm or it can be reset by entering in P1109E from Installer program mode.