AAP Elite S series Spezifikationen Seite 35

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 103
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 34
Page 35
Note: P769E is the same as above but applies to Area B Time Zone Arm/Disarm
Note: P869E is the same as above but applies to Area C Time Zone Arm/Disarm
Note: P969E is the same as above but applies to Area D Time Zone Arm/Disarm
AREA "A" MISCELLANEOUS KEYPAD OPTIONS - P670E
AREA "B" MISCELLANEOUS KEYPAD OPTIONS - P770E
AREA "C" MISCELLANEOUS KEYPAD OPTIONS - P870E
AREA "D" MISCELLANEOUS KEYPAD OPTIONS - P970E
P670E 1 = Cannot Arm if not Ready (Zone/s unsealed)
2 = “Arm” key required before code to arm
3 = “Stay” key required before code to arm Stay Mode
4 = “Code” required to arm area
5 = “Code” required to “Bypass”
6 = “Control/Chime” Button disables "Chime" mode
7 = Spare
8 = Cannot arm if Supervise fail active
Option 1 Cannot Arm if not Ready (Zone/s unsealed) - If this option is turned on it will inhibit arming of Area “A”
if any zone in area A is unsealed (Not Ready). If the option is off, the area can be armed with zones
unsealed but the panel will either auto-bypass the zone or go into alarm at the end of the exit delay
depending upon other option settings. If required, certain zones can be exempted from this feature if
they are in low security areas, allowing the area to be armed with a zone/s unsealed, by programming
the zone group option at addresses P431E-P450E option 7. This feature does not apply to Stay mode.
Option 2Arm” key required before code to arm - If this option is turned on, the "ARM" key must be pressed
before the code to arm Area "A". This option should be enabled where the keypad is assigned to more
than one area.
Option 3Stay” key required before code to arm Stay Mode - If this option is turned on, the "STAY" key must
be pressed before the code to arm Area "A" Stay Mode. This option should be enabled where the
keypad is assigned to more than one area. If this option is turned off, Stay mode is armed by pressing
the Stay button only. When Arming Stay Mode, if the user presses the “Enter” button during the exit
delay, this will cancel any remaining exit delay time and make all Stay zones instant, even if they have
an entry delay time programmed. The cancelled delays will only apply for that armed period.
Option 4Code” required to arm area - If this option is off the area can be armed with a single press of the
“Arm” button, i.e. code not required to arm. If this option is on, a valid Area "A" user code is required to
arm the area and the single button arming is disabled.
Option 5Code” required to “bypass” zones - If this option is off, any zone that is allowed to be Bypassed can
be bypassed by simply pressing the Bypass button, i.e. no code is required. If this option is on, a valid
Area "A" user code must be entered following pressing of the “Bypass” button to allow zone bypasses to
occur. When bypassing zones, the user code must be assigned to the same area as the zone otherwise
they will not be allowed to bypass the zone.
Option 6 “Control/Chime” Button disables "Chime" mode - If this option is enabled, pressing the “CHIME”
button (Crow keypad) or pressing the “CONTROL” button followed by the “PROGRAM” button (AAP
keypad) for two seconds will disable the chime alarms for the area assigned to the keypad. When chime
mode is disabled the “CHIME OFF” message will appear on the LCD display. To restore the chime
function simply press the CHIME or CONTROL & PROGRAM buttons again. If this option is turned off,
then Chime mode cannot be disabled at the keypad.
Option 7 Spare
Option 8 Cannot arm if Supervise fail active - If there is a wireless detector in this Area that has failed on the
supervise timer (P919E or P920E) and this option is turned on, arming of Area “A” will be inhibited until
the supervise alarm has been reset. If the option is off, the area can be armed during a supervise fail
condition.
Note: P770E is the same as above but applies to Area B Keypad options
Note: P870E is the same as above but applies to Area C Keypad options
Note: P970E is the same as above but applies to Area D Keypad options
Seitenansicht 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 102 103

Kommentare zu diesen Handbüchern